Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
1.
Dental press j. orthod. (Impr.) ; 21(1): 42-46, Jan.-Feb. 2016. tab
Article in English | LILACS | ID: lil-777514

ABSTRACT

Introduction: The aim of this in vitro study was to compare the elastic properties of the load-deflection ratio of orthodontic wires of different lot numbers and the same commercial brand. Methods: A total of 40 nickel-titanium (NiTi) wire segments (Morelli OrtodontiaTM - Sorocaba, SP, Brazil), 0.016-in in diameter were used. Groups were sorted according to lot numbers (lots 1, 2, 3 and 4). 28-mm length segments from the straight portion (ends) of archwires were used. Deflection tests were performed in an EMIC universal testing machine with 5-N load cell at 1 mm/minute speed. Force at deactivation was recorded at 0.5, 1, 2 and 3 mm deflection. Analysis of variance (ANOVA) was used to compare differences between group means. Results: When comparing the force of groups at the same deflection (3, 2 and 1 mm), during deactivation, no statistical differences were found. Conclusion: There are no changes in the elastic properties of different lots of the same commercial brand; thus, the use of different lots of the orthodontic wires used in this research does not compromise the final outcomes of the load-deflection ratio.


Introdução: o objetivo deste estudo experimental in vitro foi comparar a as propriedades elásticas da relação carga/deflexão para fios de diferentes lotes de uma mesma marca comercial. Métodos: foram selecionados quarenta segmentos de arcos de níquel-titânio superelástico (NiTi) (Morelli Ortodontia, Sorocaba/SP, Brasil), com diâmetro de 0,016". Os grupos foram ordenados de acordo com os lotes (lotes 1, 2, 3 e 4). Foram utilizados segmentos com 28mm de comprimento da parte reta (extremidades) dos arcos pré-contornados. Os testes de deflexão foram realizados em uma máquina universal de ensaios EMIC, com célula de carga de 5N e velocidade de 1mm/minuto. A força durante a desativação foi registrada nas deflexões de 0,5; 1; 2 e 3mm. O teste de Análise da Variância (ANOVA) foi utilizado para comparar diferenças entre as médias dos grupos. Resultados: na comparação de força dos lotes em um mesmo ponto de deflexão (3, 2 e 1mm), durante a desativação, não houve diferenças estatísticas. Conclusões: não ocorre alteração nas propriedades elásticas em diferentes lotes da mesma marca. Assim, o uso de diferentes lotes dos fios ortodônticos utilizados nesta pesquisa não comprometeu o resultado final da relação carga/deflexão.


Subject(s)
Humans , Orthodontic Wires , Titanium , Materials Testing , Brazil , Dental Alloys , Dental Stress Analysis , Elasticity , Nickel
2.
Ortho Sci., Orthod. sci. pract ; 7(25): 71-75, 2014. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-729344

ABSTRACT

A Classe II é uma má oclusão muito frequente na população que procura o tratamento ortodôntico. Pode ser caracterizada por um desequilíbrio das estruturas dentárias e/ou esqueléticas. Dentre as opções para o tratamento desta má oclusão podemos citar o aparelho de protração mandibular (APM) que propicia alterações esqueléticas e/ou dentoalveolares. Sendo assim, este artigo se propõe expor um caso clínico de paciente portadora de má oclusão de Classe II, 2ª divisão, tratada com o APM unilateral para correção dentária e do desvio de linha média inferior.


The treatment of Class II malocclusion is frequent in seeking patients orthodontic treatment. This malocclusion is characterized by dental or skeletal disorders. Among the treatment options, the mandibular protraction appliance (MPA) is an alternative that provides skeletal and/or dentoalveolar changes. There fore this article aimed at presenting a case report of Class II division II malocclusion treated with unilateral mandibular protraction appliance for dental correction and lower midline deviation.


Subject(s)
Humans , Female , Adult , Malocclusion, Angle Class II , Orthodontic Appliances, Functional , Orthodontics, Corrective
3.
Rev. Clín. Ortod. Dent. Press ; 12(4): 9-13, ago.-set. 2013. ilus
Article in Portuguese | LILACS, BBO | ID: biblio-855922

ABSTRACT

Para melhor entendimento do uso de carga imediata em mini-implantes ortodônticos, consideramos de importância analisar, inicialmente, os fatores relacionados à estabilidade do mini-implante (MI). O sucesso na sua instalação encontra-se em torno de 85%, pois depende de fatores distintos e relacionados ao MI, ao profissional e ao paciente1,2 (Fig. 1).As melhorias nas características relacionadas às suas dimensões e desenhos têm contribuído para facilitar a seleção dos MIs mais apropriados ao uso na Ortodontia3. Ao longo do tempo, a aquisição de maior habilidade quanto à técnica de inserção torna o profissional mais apto, aumentando a porcentagem de sucesso na sua instalação4,5,6. Porém, os fatores da estabilidade relacionados com o paciente não sofrem influência do processo evolutivo em habilidade técnica ou do dispositivo. Consideram-se como relacionados ao paciente: a espessura da cortical, a largura do septo inter-radicular e a higiene bucal7,8...


Subject(s)
Immediate Dental Implant Loading , Dental Implants
4.
Ortodontia ; 46(4): 350-354, jul.-ago. 2013. ilus, graf
Article in Portuguese | LILACS, BBO | ID: lil-714212

ABSTRACT

Este estudo teve como principal objetivo avaliar o uso, naatualidade, da classificação de Angle, por 37 especialistas em Ortodontia.Para essa finalidade, foi utilizado um questionário, composto de três fotosque abrangiam apenas as relações entre os dentes posteriores, sendoque, nos três casos, a relação molar apresentada era de Classe I. Oexaminador deveria obedecer à classificação da máoclusão de Angle. Naavaliação do questionário, verificou-se que aproximadamente 69% dosexaminadores classificaram o relacionamento anteroposterior entre osmolares como Classe I, enquanto que 28% apontaram ser Classe II,e 3%apontaram ser Classe III.Entre os examinadores, 27% afirmaram utilizarapenas a classificação de Angle para fins de diagnóstico, concluindo que73% não utilizam apenas o referido sistema para a mesma finalidade. Oestudo mostrou que grande parte dos profissionais avaliados conheceos conceitos de Angle, embora não os utilize como única forma dediagnóstico de má-oclusão, priorizando outros métodos.


The aim of this study was to evaluate the use, innowadays, of the Angle classification by 37 orthodontists. For thispurpose, a questionnaire was used, consisting of three photos, coveringonly the relations between the posterior teeth, whereas in all threecases, the molar relation was Class I, which the examiner should haveclassified as the malocclusion of Angle. In the assessment questionnaire,it has been found that approximately 69% of examiners classified theanteroposterior relationship between molars as Class I, while 28%indicated as Class II and 3%, as Class III. Among the examiners,27% reported to use only the Angle classification for the diagnose,thus concluding that 73% do not use only this system for the samepurpose. This study showed that most assessed professionals know theconcepts of Angle, but do not use it as the only way for the diagnosisof malocclusion, prioritizing other methods.


Subject(s)
Malocclusion/diagnosis , Surveys and Questionnaires
5.
Rev. Clín. Ortod. Dent. Press ; 12(2): 84-91, abr.-maio 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-855939

ABSTRACT

Para a adequação de espaços edêntulos, principalmente na região anterior das arcadas dentárias, torna-se importante minimizar os efeitos colaterais nas unidades de ancoragem durante a movimentação ortodôntica e, consequentemente, promover a estética e função ao longo do tratamento. O objetivo desse trabalho é apresentar a versatilidade dos mini-implantes em atender a esses objetivos, por meio de um caso clínico com agenesia dos incisivos laterais superiores permanentes, em que a estratégia terapêutica envolveu a reposição protética na área.


Subject(s)
Humans , Female , Young Adult , Anodontia/therapy , Dental Implants/methods , Orthodontics, Corrective , Orthodontic Anchorage Procedures/methods
6.
Rev. Clín. Ortod. Dent. Press ; 12(1): 52-59, fev.- mar. 2013. ilus, tab
Article in Portuguese | LILACS, BBO | ID: lil-681630

ABSTRACT

O tratamento da mordida aberta anterior em pacientes adultos apresenta muitas limitações. A terapia cirúrgica é a mais adequada para esses casos; no entanto, por razões psicológicas, alguns pacientes rejeitam essa forma de tratamento. Diante da necessidade de tratamento desses pacientes, esse artigo se propõe a apresentar um caso de mordida aberta anterior severa tratada com a técnica Multiloop Edgewise Archwire (MEAW). Ao final do tratamento foi atingida oclusão ideal, com função adequada e estética agradável, demonstrando que a técnica aplicada foi efetiva para a correção da mordida aberta anterior, sem cirurgia.


Subject(s)
Humans , Female , Young Adult , Orthodontic Appliances/standards , Open Bite/therapy , Orthodontics, Corrective/methods , Patient Care Planning , Treatment Outcome
7.
Ortho Sci., Orthod. sci. pract ; 6(24): 473-477, 2013. ilus, tab, graf
Article in Portuguese | LILACS, BBO | ID: lil-729336

ABSTRACT

O objetivo deste estudo foi avaliar, comparativamente, a relação carga/deflexão dos fios ortodônticos de níquel-titânio superelásticos metálicos e estéticos, das marcas Orthometric® e GAC-Dentsply®. Foram avaliados fios ortodônticos 0,016” de níquel-titânio em arcos pré-contornados, com e sem revestimento. As amostras totalizaram 20 segmentos de fios de 28 mm, divididos em 4 grupos: Grupo 1 - Orthometric – Marília/SP/Brasil – estético, Grupo 2 - Orthometric - metálico superelásticos, Grupo 3 - GAC / Dentsply – New York/NY/USA – estético e Grupo 4 - GAC – Dentsply - metálico superelástico. Foi utilizado como corpo de prova um dispositivo em acrílico com bráquetes metálicos Edgewise slot .022” (Dental Morelli Ltda., Sorocaba/SP/Brasil). O teste de deflexão foi realizado na máquina de ensaio universal Kratos a uma velocidade de 0,5 mm/min, com célula de carga de cinco Newtons, utilizando-se uma ponta com extremidade cônica de 8 mm de diâmetro. A análise da relação carga/deflexão foi mensurada a cada 0,5 mm, entre 0 e 3 mm de deflexão do fio. Os resultados deste estudo demonstraram que não houve diferença estatisticamente significante entre os grupos de acordo com o Teste ANOVA, para a ativação (p= 0,774) e desativação (p=0,367), considerando a = 0,05. Concluí-se que todos os grupos possuem valores da proporção carga/deflexão semelhantes.


The aim of this study was to perform a comparative analysis of the load-deflection relation between coated (aesthetic) and uncoated nickel-titanium orthodontic wires from two different brands: Orthometric® (Marília/SP/Brazil) and GAC-Dentsply® (NewYork/NY/USA). An assessment of nickel-titanium orthodontic wires of 0.016” on pre-countered arches was performed. The sample was composed of 20 segments of 0.016” nickel-titanium orthodontic arches divided into 4 groups: Group 1 - Orthometric® – aesthetic; Group 2 - Orthometric® -superelastic alloy, Group 3 - GAC/ Dentsply – aesthetic; Group 4 - GAC – Dentsply - superelastic alloy. An acrylic device with metal brackets was used as specimen. The deflection test was carried out in a Kratos universal testing machine, at a 0.5 mm/min speed with a 5 Newtons load cell using a 8mm tapered tip. The analysis of the load/deflection relation was measured every 0.5 mm between 0 and 3 mm of wire deflection. The results of this study showed no statistically significant difference between groups according to ANOVA test for the activation (p = 0.774) and deactivation (p = 0.367), considering a = 0.05. It was concluded that all groups have similar values for load/deflection ratio


Subject(s)
Dental Alloys , Orthodontic Wires , Orthodontics
8.
Ortho Sci., Orthod. sci. pract ; 5(19): 433-443, 2012. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-852858

ABSTRACT

A mordida aberta anterior é uma das más oclusões mais difíceis de tratamento devido a sua complexidade. A terapêutica adotada depende da idade do paciente, da gravidade da má oclusão e da etiologia. As técnicas podem variar desde a correção através da modificação dentoalveolar até o tratamento ortodôntico cirúrgico. O presente trabalho tem por finalidade apresentar a técnica Multiloop Edgewise Archwire (MEAW), através de um caso clínico de um paciente adulto com mordida aberta esquelética. A técnica MEAW mostrou-se eficiente no tratamento da mordida aberta anterior esquelética, no entanto é importante que o ortodontista tenha consciência da limitação da técnica, levando em consideração a queixa principal e a expectativa do paciente.


The anterior open bite malocclusions that most concerns the dentist due to its complexity. Adopted therapy depends on the age of the patient, the severity of malocclusion and its etiology. The techniques can vary from the correction by dentoalveolar amendment to surgical orthodontic treatment. The present work aims at presenting the Multiloop Edgewise Archwire technique (MEAW) through a clinical case of an adult patient with skeletal open bite. MEAW technique proved to be efficient in the treatment of skeletal anterior open bite however, it is important that the orthodontist has awareness of technical limitation, taking into consideration patient’s chief complaint and expectation.


Subject(s)
Humans , Male , Adult , Malocclusion, Angle Class II , Open Bite , Orthodontics
SELECTION OF CITATIONS
SEARCH DETAIL